IEEE Commands Power Supply NGMO
4.00 / 07-2004 5-25
Com-
mand
Parameter Par. value Description Def. SCPI
38400
MIN 300
DEFault 9600
MAX 38400
:SYSTem :COMM-
unicate
:SERial :DATabits <CHAR_VAL> or
<NUM_VAL>
Sets serial data
length
8
7 7 bits
8 8 bits
MIN 7 bits
* DEFault 8 bits
MAX 8 bits
DISPlay Sets LCD to:
Serial count of
Databits
:SYSTem :COMM-
unicate
:SERial :DATabits
?
<CHAR_VAL> Queries serial
data length
Results:
7
8
MIN 7
DEFault 8
MAX 8
:SYSTem :COMM-
unicate
:SERial :PARity <CHAR_VAL> Sets serial parity NONE
NONE None
ODD Odd
EVEN Even
MIN None
* DEFault None
MAX Even
DISPlay Sets LCD to:
Serial parity
:SYSTem :COMM-
unicate
:SERial :PARity? <CHAR_VAL> Queries serial
parity
Results:
NONE
ODD
EVEN
MIN NONE
DEFault NONE
MAX EVEN
:SYSTem :COMM-
unicate
:SERial :STOPbits <CHAR_VAL> or
<NUM_VAL>
Sets number of
stopbits
1
1 1 stopbits
2 2 stopbits
MIN 1 stopbits
* DEFault 1 stopbits