25
E-09
7.A/D Test 1 (Bender, Modulation)
Verify bender and modulation operation.
When entering this test, first make sure the Bender control has not been
operated (flipped down). (This is because the A/D value when entering the
test is read as the midpoint voltage.)
(“OK” is not displayed unless the tests are conducted in the sequence of
Bender left, Bender right, and Modulation.)
fig.lcd-t16-bend
1. Move the Bender control all the way to the left, and when the value “-
128” is displayed, a clicking sound is heard.
2. Move the Bender control all the way to the right, and when the value
“127” is displayed, a clicking sound is heard.
3. When left and right testing are both finished, “OK” is displayed.
4. Move the Modulation control all the way toward the back, and when the
value “127” is displayed, a clicking sound is heard.
5. Return the Modulation control back toward the front, and when the value
“0” is displayed, a clicking sound is heard, “OK” is displayed, and
operation advances to the next test.
8.Pedal Test (Hold Pedal)
fig.lcd-t17-hold
1. Connect a Hold pedal to FOOT SWITCH at the rear of the unit.
2. Depressing the Hold pedal displays the value “127”, and a clicking sound
is heard.
3. Return the Hold pedal, and when the value “0” is displayed, a clicking
sound is heard, “OK” is displayed, and operation automatically advances
to the next test.
9.SWITCH & LED Test
fig.lcd-t18-sw
Perform a check of the switches and LEDs.
Entering this test makes all LEDs light up.
1. Pressing the switches provided with LEDs makes the LEDs go dark.
The number of switches remaining unpressed is displayed at the top
right of the screen.
<FILTER>, <ENV>, <BACKING>, and <EFFECT> LEDs = [SELECT]
switch (button)
2. When all switches have been pressed, operation automatically advances
to the next test.
When more than one switch is pressed simultaneously, “WARNING !!” is
displayed on the LCD screen.
If this happens, press the [USER PROG] + [FAMILY < ] buttons, choose the
“9.SWITCH & LED Test” item again, and redo the test.
10.KEYBOARD Test
fig.lcd-t19-piano
1. Make sure that all keys produce sound when played.
Also make sure that the volume changes according to the velocity with
which the keys are played.
2. Pressing the [TEMPO + / YES] button changes the tone from PIANO to
ORGAN.
fig.lcd-t20-orgn
3. Make sure that all keys produce sound when played.
4. Pressing the [TEMPO + / YES] button proceeds to the next test.
BEND: 0 MOD: 0
PEDAL: 0
Sw & LED 52
KEYBOARD PIANO
KEYBOARD ORGAN