Correcting for Misalignment in Bidirectional Printing
18
2. Changes to the Users Manual2. Changes to the User’s Manual
2. Press to decide a correction value for the selected item from H1 to H6 (from H1 to H3 for
the LEC-300/300A).
To decide a Correction Value
Choose the value that produces the least misalignment of 2 lines. When wavering between two numbers, select half value.
H3
H4
H5
H6
H2
H1
NO.1
H3
H4
H2
H1
NO.2
H5
H6
H3
H2
H1
NO.3
H1
NO.1
If the Printing-test Results Are Dicult to Interpret
Examine the results from dierent angles in a well-lighted location. Take advantage of reected light to enable
visual checking.
If you cannot see "H5" or "H6" (“H3”) (such as when using white media with no shine)
You may not be able to see “H5” or “H6” (“H3” for the LEC-300/300A) when using certain media, such as white
media with no luster. In this case, set “H5” and “H6” (“H3” for the LEC-300/300A) to the same value as “H4” (“H2”
for the LEC-300/300A).
Choose the value that produces the least misalignment.
= Current correction value
3. Press .
This completes the conguration of [SETTING NO.1].
4. Press .
5. In the same manner as performed for [SETTING NO.1], repeat steps 1 to 4 to set the correction values for
[SETTING NO.2] to [SETTING NO.8].
LEJ-640
After you have congured up to [SETTING NO.8], attach front cover 2. If you are using rigid media, press
and pull
back the media to the appropriate position.
6. Press in this order to go back to the original screen.