EasyManua.ls Logo

Roland RSS M-300 - Page 76

Roland RSS M-300
225 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
76
Dynamics
Dynamics
The key-in signal used by the compressor is taken from the post-
gate point of the channel itself or any of the following sources:
CH1–32 Direct out
AUX1–8, MTX1–4, MAIN L/R/C output
REAC A IN1–40
REAC B IN1–40
CONSOLE IN1–12
ig.CompKeyInFlow.eps
To select the key-in signal, use the KEY-IN SELECT popup.
1.
Move the cursor to the KEY-IN SELECT popup button, and
press [ENTER].
fig.PopKeyInguide2.eps
The KEY-IN SELECT popup will appear.
Current key indication
This indicates the current key.
Dynamics type indication
This indicates the type of dynamics to which the KEY-IN
SELECT popup applies.
Key-in signal select buttons
These buttons select the channel that will be used as the
key-in signal.
The function buttons have the following operations:
2.
Move the cursor to the desired key-in signal select
button, and press [ENTER] to select it.
3.
Press [F8 (CLOSE)] to close the popup.
If you want the channel itself to be its own key-in signal, press
[F6 (SELCT SELF)].
1.
Access the COMPRESSOR popup.
fig.PopComp.eps
2.
Use the filter type select buttons to select the filter type.
3.
Use the FREQ/Q knobs, in the KEY-IN FILTER section, to
adjust the filter.
4.
Use the ON button, in the KEY-IN FILTER section, to turn
the filter on.
If you turn [F7 (KEY-IN SOLO)] on, you can hear the output signal
of the key-in filter via the M-300’s monitor output.
[F7 (KEY-IN SOLO)] will automatically be cancelled when you
close the COMPRESSOR popup.
Selecting the key-in signal for the
compressor
[F1 (CH1-32)]
Displays CH1–32 as the key-in signal select
buttons.
[F2 (BUS)] Displays AUX1–8, MTX1–4, and MAIN L/R/C as
the key-in signal select buttons.
[F3 (REAC A)] Displays REAC A IN1–40 as the key-in signal
select buttons.
[F4 (REAC B)] Displays REAC B IN1–40 as the key-in signal
select buttons.
[F5 (CONSOLE)] Displays CONSOLE IN1–12as the key-in signal
select buttons.
PHASE HPF COMPAT T
TO SOLO
KEY-IN
SOLO
GATE/
EXP
- SELF POST GATE
- CH 1-32 DIRECT OUT
- REAC A IN1–40
- REAC B IN1–40
- CONSOLE IN1–12
KEY-IN
FILTER
21 3
1
2
3
[F6 (SELECT SELF)]
Selects the channel itself as its own key-in
signal.
[F8 (CLOSE)] Closes the popup.
Using key-in filter
M-300_e.book 76 ページ 2010年6月24日 木曜日 午後2時26分

Table of Contents

Related product manuals