Appendices
84 S-4000 Digital Snake Owner’s Manual
S-4000S and S-4000H Units: System Status Indicators
Indicator Status Definition Troubleshooting Action
REAC Lit Communication is
established
None (normal operation)
Dark System power-up None (normal operation)
Flashing No REAC
communication
Make sure all REAC devices are turned on
Check Cat5e cable connections
Check the Cat5e cable(s) for damage
Is the proper cable type being used? (See Page
51)
If a switching hub is used, is it working?
If a switching hub is used, is it properly
connected? (See Page 53, 76)
If a switching hub is used, does it have the proper
specification? (See Appendix C)
CTRL Lit RS-232C
communication
established
None (normal operation)
Dark No device is
connected to
REMOTE jack
None (normal operation)
Flashing No RS-232C
communication
Check the RS-232C cable for damage
Are you using an RS-232C cable with the proper
wiring? (See Appendix B)
If connected to a computer, is the computer on?
Is the computer’s RS-232C port functioning
properly?
S-4000S and S-4000H Units: ALARM Indicator
Indicator Status Definition Troubleshooting Action
ALARM Lit Abnormal (high)
temperature
detected
Make sure the intake and/or exhaust vents on the
unit are not blocked.
Shut down the unit to prevent overheating and
damage
An exhaust fan (or
fans) has stopped
working
Shut down the unit to prevent overheating and
damage
NOTE: If ALARM lights, see the S-4000R error indicators for more specific information