86 S-4000 Digital Snake Owner’s Manual
S-4000R Unit: Error Indicators
Indicator Status Definition Troubleshooting Action
CLIP 2 Lit An exhaust fan (or
fans) on the Master
REAC unit has
stopped working
Shut down the unit to prevent overheating and
damage
Flashing Recovery from the
above error
None
CLIP 3 Lit Abnormal (high)
temperature
detected on the
Master REAC unit
Make sure the intake and/or exhaust vents on the
Master REAC unit are not blocked
Shut down the unit to prevent overheating and
damage
Flashing Recovery from the
above error
None
CLIP 4/
SIG 4
Lit REAC packets error
detected on the unit
connected to the
S-4000R
Check MAIN and BACKUP REAC cabling
Check MAIN and BACKUP REAC connections
Check in-line switching hub (if used) on MAIN
and BACKUP REAC connections
SIG 2 Lit An exhaust fan (or
fans) on a Slave/
Split REAC unit has
stopped working
Shut down the unit(s) to prevent overheating and
damage
Flashing Recovery from the
above error
None
SIG 3 Lit Abnormal (high)
temperature
detected on a Slave/
Split REAC unit
Make sure the intake and/or exhaust vents on the
Slave/Split units are not blocked
Shut down the unit(s) to prevent overheating and
damage
Flashing Recovery from the
above error
None
LED Display Flashes
“Er”
This happens
whenever one of the
previously described
S-4000R error
indicators lights or
flashes
Look for the source of the error
Press CLIP CLEAR•ENTER to return to normal
S-4000R operation