EasyManua.ls Logo

Roland V-Drums TD-20 - Chapter 4. Effect Settings; Effects On;Off Switches; Compressor and EQ Application

Roland V-Drums TD-20
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38
Chapter 4. Effect Settings
These switches allow you to turn all individual effects and
master effects on/off within each drum kit.
fig.04-001_70
1.
Press [EFFECTS SWITCH].
[EFFECTS SWITCH] lights, and the “EFFECTS SWITCH”
screen appears.
2.
Press [F1]–[F5] to turn the following on/off.
[F1]: Pad Compressor (*1)
[F2]: Pad Equalizer (*1)
[F3]: Ambience
[F4]: Multi-effects
[F5]: Master Effects
3.
Press [EXIT] to return to the “DRUM KIT”
screen.
* Effect on/off status appears in the “DRUM KIT” screen.
fig.04-002e_70
* 1: All pad compressors or pad equalizers are turned on/off
simultaneously.
An individual Compressor and EQ can be applied to every
sound assigned to a trigger input.
1.
Press [COMP/EQ].
[COMP/EQ] lights.
2.
Strike the pad you wish to set.
3.
Press [F2], [F3], or [CURSOR] to select the
parameter.
Function Buttons
[F2 (COMP)]
Pad compressor parameters appear.
[F3 (EQ)]
Pad equalizer parameters appear.
4.
Use [+/-] or [VALUE] to adjust the setting.
5.
Press [F1] and/or [F4] to turn on the
compressor/equalizer for each trigger input.
[F1]:
Turns the pad compressor on/off
[F4]:
Turns the pad equalizer on/off
,
COMP/EQ setting is ON, EFFECTS SWITCH is ON
Effect applies.
,
COMP/EQ setting is ON, EFFECTS SWITCH is OFF
Effect does not apply.
COMP/EQ setting is OFF
Effect does not apply.
* Pressing [F5 (H & R)], you can choose to set the head and rim
simultaneously or individually.
The sound may be distorted in a certain setting.
Effects On and Off Switches
[EFFECTS SWITCH]
ON OFF
Using the Compressor and
EQ [COMP/EQ]
TD-20_Ref_e.book 38 ページ 2004年3月5日 金曜日 午後7時3分

Table of Contents

Other manuals for Roland V-Drums TD-20

Related product manuals