How to resolve a Controller Malfunction on RollSeal?
- BBrian RodriguezSep 12, 2025
To resolve a Controller Malfunction, reset the controller.
How to resolve a Controller Malfunction on RollSeal?
To resolve a Controller Malfunction, reset the controller.
What to do if there is an Encoder Fault when closing the RollSeal SC-650 Controller?
If there is an Encoder Fault when closing, check the DC harness and make sure the optics are clean.
How to fix Closing, Direction Fault on RollSeal SC-650?
If there is a Direction Fault when closing, reverse two phases to the motor.
| Brand | RollSeal |
|---|---|
| Model | SC-650 |
| Category | Controller |
| Language | English |
Details the location and function of the main power switch and fuse for the controller and automatic doors.
Describes the display's four selectable readings: Actual Position, Open Speed, Close Speed, and Cycle Counts.
Explains various display readings like Software Version, Actual Position, Unknown Position, Assumed Position, and Jog Mode.
Guides on entering Program Mode to set parameters like Close Time Delay, Acceleration, and Deceleration.
Details adjusting acceleration and deceleration ranges (P2, P3) for smooth door operation.
Explains SWX1 for Safety Action/Encoder Selection and SWX2/J1 for Voltage Selection.
Step-by-step guide to set the door's full open and closed position limits using controller buttons.
Explains how LED segments on the display indicate the status of various inputs for troubleshooting.
Lists error codes, their descriptions, and recommended actions for diagnosing and resolving faults.
Provides steps for unpacking, mounting, and connecting the controller before initial power-up.
Explains how to mount and connect the power disconnect to the controller and electrical supply.
Outlines final checks before operation, including fuse insertion, power application, and limit setup.
Explains AC power connection, including voltage selection jumper settings for the controller.