EasyManua.ls Logo

Rosemount 3051SFA - Page 110

Rosemount 3051SFA
268 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reference Manual
00809-0100-4809, Rev DA
Appendix A: Specifications and Reference Data
September 2015
102
Specifications and Reference Data
Static pressure range D 1-7
A
(7)
None • • ★
D Absolute 0 to 800 psia (0 to 55.2 bar) — • ★
E
(8)
Absolute 0 to 3626 psia (0 to 250 bar) — • ★
J Gage -14.2 to 800 psig (-0.979 to 55.2 bar) — • ★
K
(8)
Gage -14.2 to 3626 psig (-0.979 to 250 bar) — • ★
Transmitter output
A 4–20 mA with digital signal based on HART protocol • • ★
F
(9)
FOUNDATION Fieldbus protocol • — ★
X
(10)(11)
Wireless • — ★
Transmitter housing style Material
Conduit entry
size
00 None (customer-supplied electrical connection)
N/A N/A • — ★
1A PlantWeb housing
Aluminum
1
/2-14 NPT • • ★
1B PlantWeb housing
Aluminum M20 ⫻ 1.5 • • ★
1J PlantWeb housing
SST
1
/2-14 NPT • • ★
1K PlantWeb housing
SST M20 ⫻ 1.5 • • ★
2A Junction Box housing
Aluminum
1
/2-14 NPT • — ★
2B Junction Box housing
Aluminum M20 ⫻ 1.5 • — ★
2E
Junction Box housing with output for remote display
and interface
Aluminum
1
/2-14 NPT • — ★
2F
Junction Box housing with output for remote display
and interface
Aluminum M20 ⫻ 1.5 • — ★
2J Junction Box housing
SST
1
/2-14 NPT • — ★
2M
Junction Box housing with output for remote display
and interface
SST
1
/2-14 NPT • — ★
5A
(12)
Wireless PlantWeb housing
Aluminum
1
/2-14 NPT • — ★
5J
(12)
Wireless PlantWeb housing
SST
1
/2-14 NPT • — ★
7J
(10)(13)
Quick Connect (A size Mini, 4-pin male termination)
N/A N/A • — ★
1C PlantWeb housing
Aluminum G
1
/2 • •
Table 2. Rosemount 3051SFC Compact Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.

Table of Contents