EasyManua.ls Logo

Rosemount 708 - APPENDIX A Specifications; Specifications

Rosemount 708
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reference Manual
00809-0100-4708, Rev AA
June 2010
A-1
Rosemount 708
Appendix A Specifications and Reference
Data
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-1
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-3
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-4
SPECIFICATIONS
Functional
Specifications
Output
WirelessHART™ acoustic, temperature states.
Humidity Limits
0 - 100% relative humidity
Temperature Limits
-40 °C to 85 °C
Transmit Rate
User selectable, 4, 8, 16, 32 seconds, or 1 to 60 min.
Physical Specifications Electrical Connections/Power Module
Replaceable, non-rechargeable, Intrinsically Safe Lithium-Thionyl
Chloride power module pack with PBT enclosure
Eight year power module life at reference conditions
(1)
Field Communicator Connections
Communication Terminals
Clips permanently fixed to power module
Materials of Construction
Enclosure
Housing
PBT/PC
Cover O-ring
Buna-N
Power Module
PBT/PC
Antenna
Integrated omnidirectional antenna
(1) Reference conditions are 70 °F (21 °C), transmit rate of once per minute, and routing data
for three additional network devices.