Controller Functionality
AYC-Qx4 family manual Page 57
The Door LED will flash
orange.
The controller is now waiting for the primary code of the user.
4) Enter the primary code
belonging to the user.
The Mode LED will flash
green.
5) Enter the assignment digit for the current user slot:
1 will activate the Lock Strike relay only deafult
2 will activate the Auxiliary relay only
3 will activate the Lock Strike and Auxiliary relays.
If the assignment digit is valid, three beeps will be heard and the
controller will return to its normal mode.
If the assignment digit is invalid, a long beep will sound and the
controller will wait for another assignment digit to be entered.
Pin Code Length / Factory Default Settings
Warning:
You must be very careful before using this command!
Changing the pin code length will also erase the entire
memory contents, including all user and special codes,
and return all codes to their factory-default settings
1) Enter the Programming
Mode.
2) Select the desired pin code length as follows:
00 – Returns to factory defaults and sets a 4 digit code.
05 - Returns to factory defaults and sets a 5 digit code.
Mode/Transmit
Door/Program
Green
Mode/Transmit
Door/Program
Green Oran
e
Mode/Transmit
Door/Program
Green Oran
e

Table of Contents

Other manuals for Rosslare AYC-Q54B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosslare AYC-Q54B and is the answer not in the manual?

Rosslare AYC-Q54B Specifications

General IconGeneral
BrandRosslare
ModelAYC-Q54B
CategoryController
LanguageEnglish

Related product manuals