d06703.fm
03 July 2019 76-10-00
Initial Issue Page 16 of 18
Copyright - BRP-Rotax GmbH & Co KG. All rights reserved.
SI-912 i-024
SI-915 i-006
SERVICE INSTRUCTION
3.3.3) Installation of optional support bracket
See Fig. 18 and Fig. 19.
Fig. 19
Step Procedure
1
Remove M6 lock nut (1) and washer (2). Remove connector bracket assy. (3) from
the fuse-box connector side of regulator B.
2 Place bracket (4) over attachment stud so that bend faces away from the fuse-box.
3 Attach with M6 washer and new M6 lock nut. Tightening torque 10 Nm (89 in.lb).
Step Procedure
4
Remove nut and O-ring from Rectifier B connector.
NOTE: O-ring is not necessary in this application and may be discarded.
5 Place connector through connector bracket (4).
6 Attach with connector nut (5). Tightening torque 10 Nm (89 in.lb).
1 Lock nut M6
2 Washer 6.4
3 Connector bracket assy.
4 Connector bracket part no. 951981