Effectivity: 914 Series BRP-Powertrain page 4-7
OM Edition 2 / Rev. 0 April 01/2010
d05037.fm
4.12) Engine on fire or fire in the engine compartment
Engine of fire In the event of fire or signs, e.g. heavy smoke:
Any shut-off of the fuel system for short periods or permanent has
to be entered by the pilot into the logbook starting date and dura-
tion of shut-off.
Step Procedure
1 Both electric fuel pumps and the main switched off.
2 The fuel valve has to be closed.
3 If the fire should extinguish it may be tried again to ac-
tuate the main fuel pumps and to start the engine (see
section Engine start).
NOTICE
If the fire starts anew the fuel system has to
be shut off immediatly.

Table of Contents

Other manuals for Rotax 914 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 914 series and is the answer not in the manual?

Rotax 914 series Specifications

General IconGeneral
Bore79.5 mm
Stroke61 mm
Compression Ratio9.0:1
Cooling SystemLiquid-cooled cylinder heads, air-cooled cylinders
Redline5800 rpm
Engine Type4-cylinder, 4-stroke
Fuel TypeAvgas 100LL
Oil SystemDry sump
Fuel Systemfuel injection
TBO (Time Between Overhauls)2000 hours
Displacement1.211 liters (1211 cc)
Power Output84.6 kW (115 hp) at 5, 800 rpm

Related product manuals