DO NOT operate the Thermal Imaging Camera when you are tired or
under the influence of alcohol, drugs or intoxicating medication.
Safety warning
The warnings, cautions and instructions in this manual do not cover all
possible conditions and situations that may occur. Logic and attention must
be applied by the operator.
3 RO thermal imaging camera overview
The RO Thermal imaging camera Thermal Imaging Camera combines surface
temperature measurement & real-time thermal imaging.
The large colour display screen provides the user with visual information
based on the current activity including an on-screen curser to accurately
locate temperature hotspots.
The RO Thermal imaging camera uses a data storage system allowing the
user to store images on the device. These can be extracted through USB to
generate reports.
Suitable for many industries including plumbing & heating (radiators,
underfloor heating, energy auditing or water damage), automotive (heated
seats and windows, high resistance in wiring, overheating wiring or
components).
4 Maintenance
Use a damp cloth and light soap to clean the outer casing of the device. Don’t
use abradant, isopropanol or solvent to clean. The lens & screen should be
cleaned with cleaning agents for professional optical glasses.
To prevent damage of the refined anti-reflective coating:
Don’t clean with force.
Use a cleaning solution for lens maintenance, such as an alcohol-based
4.1 Cleaning
4.2 Lens maintenance

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rothenberger RO and is the answer not in the manual?

Rothenberger RO Specifications

General IconGeneral
Display screen2.8-inch full-view TFT display
LCD resolution320×240
Colour paletteRainbow, iron oxide red, cold col­ our, black & white, white & black
Temperature measurement range-20℃ to 300℃ (-4°F to 572°F)
EmissivityAdjustable from 0.01 to 1.00
Measurement accuracy±2℃/±2% (whichever is greater)
Infrared image resolution220×160
Visible image resolution35200 pixel
Field angle35°×26°
Focal distance (shortest)0.15m
Thermal sensitivity0.07℃
Frame rate of thermal images9Hz
Focus modeFixed
Wavelength coverage8-14um
Storage capacityBuilt-in memory 3GB
File formatJPG
Setting commandUnit, language, date, time, information
LanguageEnglish & French
USBMicro USB 2.0
Power supplyBuilt-in chargeable 18650 battery Detachable
Automatic power-off timeSelectable: 5 minutes/20 minutes/ not power off automatically
Working time2-3 hours
Weight and Dimensions IconWeight and Dimensions
Product size96mm×72mm×226mm