50
6.2.2 Maintenance & Inspection
Ordinary inspection
Item
Description
Inspect
before
use
First
month
Every 6
months
Every
year
Planning
tool
Mill or replace the blade
Replace the cable if it is broken
Retighten mechanical connections
Heating
plate
Rejoined the cable and socket
Clean surface of heating plate, recoat PTFE
layer again if necessary
Retighten mechanical connections
Temp.
control
system
Checkout the temperature indicator
Replace the cable if it is broken
Hydraulic
system
Checkout pressure gauge
Replace seals if the hydraulic unit is leak
Clean the filter
Make sure the oil is enough for operation
Change the hydraulic oil
Replace if the oil hose is breakage
Basic
Frame
Retighten screws in the end of frame axis
Spray antirust paint again if necessary
Power
Supply
Press the testing button of circuit protector to
make sure it can working normally
Replace the cable if it is broken
“●”………… maintenance period