OPC90 Server
7.25 Remote Control Memory (RCM)
The RCM OPC90 block is used to retrieve and control the exception reported
output from Bailey Remote Control Memory blocks (function code 62).
Restrictions: This OPC90 block can be utilized with all Bailey interface types
except serial port module (SPM & CPM02).
TAGNAME TYPE ACCESS DESCRIPTION
ADDR_RING VT_I2 Config/Read Bailey ring address.
ADDR_NODE VT_I2 Config/Read Bailey node address.
ADDR_MODULE VT_I2 Config/Read Bailey module address.
ADDR_BLOCK VT_I2 Config/Read Bailey block address.
F1LSD0 VT_BSTR Config/Read Feedback 1 state zero logic state descriptor.
F1LSD1 VT_BSTR Config/Read Feedback 1 state one logic state descriptor.
OUTLSD0 VT_BSTR Config/Read Output state zero logic state descriptor.
OUTLSD1 VT_BSTR Config/Read Output state one logic state descriptor.
MESSAGE VT_BSTR Read Provides the block operational message.
TAG VT_BSTR Read Provides the block name.
TAGLONG VT_BSTR Read Provides the block long OPC path name.
TAGDESC VT_BSTR Read Provides the block descriptor.
FACE_TYPE VT_I2 Read Faceplate type (value of RCM block S8).
QUALITY VT_BOOL Read Current quality of Bailey values (0-good, 1-bad).
DISC_LIM VT_BOOL Read Discrete alarm state.
DISC_ACT VT_BOOL Read Alarm active indicator.
OUT VT_BOOL Read/Write Bailey RCM discrete output value (see note 1).
OUT_TEXT VT_BSTR Read/Write Bailey RCM discrete output value as a string
(see note 2).
RED_CMD VT_BSTR Read/Write Red tag command (see red tag users section).
RED_TAG VT_BOOL Read Red tag indicator (0 – no, 1 – yes).
RED_USERS VT_BSTR Read Red tag users (current user names or codes).
F1 VT_BOOL Read State of feedback.
F1_TEXT VT_BSTR Read State of feedback number 1 as a string.
SET_PERM VT_BOOL Read Set permissive.
OVR_STATUS VT_BOOL Read Override status indicator.
Notes:
1.) OPC90 uses pulse reset and pulse set commands when commanding the state of the
RCM output. When writing a zero to reset the output, a pulse reset command (5) is
actually sent to the RCM block by OPC90. Likewise writing one to set the output, a pulse
set command (6) is sent. Some older style drivers force the client to sent a 5 and 6 to
reset and set the RCM output. For compatibility when converting from such older style
drivers to OPC90, it can be configured to also accept values of 5 and 6 for commanding
the output reset and set. To enable this ability, the RCM.OUT parameter type must be
changed from its default setting of BIT to another multi-bit type such as INT. Right click
on the RCM.OUT attribute and select properties to make this change. Note that OPC90
will always report the value of OUT as 0 or 1 regardless of whether it is written as 0, 1, 5
or 6.
2.) Text strings can be written to this tag to control the RCM output. Valid text strings are the
OUTLSD0 and OUTLSD1 settings along with “0”, “1”, “5”, “6”, “Off”, “On”, “Reset”, “Set”,
“Zero”, “One”, “False” and “True”. Writing any of these strings is case insensitive.