J Line Pump
Horizontal Double Suction Centrifugal Pump API 610 Process Pump
65 V1.032818
Lubricate with grease or oil the inner diameter of the impeller wear ring and the
outer diameter of the impeller eye and place the impeller wear ring.
CASE
11. Insert the coupling side (radial) case wear ring into the case from the non-coupling side until
it fits in its fitting in the case.
Figure 8.11. Inserting the coupling side (radial) case wear ring into the case.
12. Insert socket set screws to fix the coupling side (radial) case wear ring to the case.
Figure 8.12. Inserting socket set screws to fix the coupling side (radial) case wear ring to the case.