J Line Pump
Horizontal Double Suction Centrifugal Pump – API 610 Process Pump
85 V1.032818
If there is no way of properly heating the bearing for installation, a bearing
installation kit approved by the bearing manufacturer can be used to perform a
bearing installation at room temperature.
Figure 8.48 Example of a bearing installation kit approved by the bearing manufacturer.
50. Insert the axial bearing sleeve over the shaft from the non-coupling side until it reaches the
second axial bearing.
Figure 8.49. Inserting the axial shaft sleeve over the shaft from the non-coupling side.