J Line Pump
Horizontal Double Suction Centrifugal Pump API 610 Process Pump
96 V1.032818
CASE
9. Insert the coupling side case wear ring in inside the case from the non-coupling side.
Figure 8.9JD. Inserting the coupling side case wear ring inside the case from the non-coupling side.
10. Insert the rotor assembly in the case from the non-coupling side.
Figure 8.10JD. Inserting the rotor assembly in the case from the non-coupling side.
When the rotor assembly is inserted inside the case, the one step design of the
impeller wear ring and the case wear ring will fix them in place inside the case.