MODEL 63504-F63C1/63604-F63C3/73504-F68C1/73604-F68C3
18
Service Days
1-03D
0~99 Days
Only for Time Clock Type,
regeneration by days.
Service Hours
1-20H
0~99
Hours
Only for Time Clock Type,
regeneration by hours.
Regeneration
Time
02:00
02:00
00:00~
23:59
Regeneration time;“:” light on.
Interval
Backwash
Times
F-00
00
0~20
Interval backwash times. For
example, F-01:indicate service 2
times, backwash 1 time.(only for
F68A3,F68C3)
Resin Volume
20L
20L
5-500L
Resin volume in brine tank (L)
Feed Water
Hardness
Yd1.2
1.2
0.1-9.9
Feed water hardness (mmol/L)
Exchange
Factor
AL.65
0.65
0.30-0.99
Relate to the raw water
hardness. When hardness is
higher, the factor is smaller.
Water Treatment
Capacity
10m
3
0~99.99
m
3
Water treatment capacity in one
circle (m
3
)
Backwash
Time
10min.
0~99∶59
Backwash time(Minute)
Brine & Slow
Rinse Time
60min.
0~99∶59
Brine & Slow rinse time(Minute)
Brine Refill
Time
5min.
0~99∶59
Brine refill time(Minute)
Fast Rinse
Time
10min.
0~99∶59
Fast rinse time(Minute)
Maximum
Interval
Regeneration
Days
H-30
30
0~40
Regenerate on the day even
through the available volume of
treated water do not drop to zero
(0).