MODEL 63504-F63C1/63604-F63C3/73504-F68C1/73604-F68C3
43
Note:
When the control valve enter into the regeneration status, all program
can be finished automatically according to the setting time; if you want
one of steps terminated early, you can press .
If water inflow too fast, the media in tank will be damaged. When water
inflow slowly, there is a sound of air emptying from drain pipeline.
After changing resin, please empty air in the resin according to the
above Step 2.
In the process of trial running, please check the water situation in all
position, ensuring there are no resin leakage.
The time for Backwash, Brine& Slow Rinse, Brine Refill and Fast Rinse
position can be set and executed according to the calculation in the
formula or suggestions from the control valve suppliers.