MODEL 63504-F63C1/63604-F63C3/73504-F68C1/73604-F68C3
46
8.Loss of
mineral
through drain
line.
A. Air in water system.
B. Bottom strainer broken.
C. Improperly sized drain
line control.
A. Assure that well system has
proper air eliminator control.
B. Replace new bottom strainer.
C. Check for proper drain rate.
9.Control cycle
continuously.
A. Locating signal wiring
breakdown.
B. Controller is faulty.
C. Foreign material stuck
the driving gear.
D. Time of regeneration
steps were set to zero.
A. Check and connect locating
signal wiring.
B. Replace controller.
C. Take out foreign material.
D. Check program setting and
reset.
10.Drain flows
continuously.
A. Internal valve leak.
B. When electricity fails to
supply, valve stops
backwash or fast rinse
position.
A. Check and repair valve body or
replace it.
B. Adjust valve to service position
or turn off bypass valve and
restart when electricity supply.
11.Interupted
or irregular
brine.
A. Water pressure too low
or not stable.
B. Injector is plugged or
faulty.
C. Air in resin tank.
D. Floccules in resin tank
during backwash.
A. Increase water pressure.
B. Clean or replace injector.
C. Check and find the reason.
D. Clean the floccules in resin
tank.
12.Water flow
out from drain
or brine pipe
after
regeneration.
A. Foreign material in
valve which makes valve
can’t be closed
completely.
B. Hard water mixed in
valve body.
C. Water pressure is too
high which result in valve
doesn’t get the right
position.
D. Under the Backwash
position, the outlet line and
A. Clean foreign material in valve
body.
B. Change valve core or sealing
ring.
C. Reduce water pressure or use
pressure release function.
D. install a check valve, solenoid
valve in front of the outlet or install
a liquid level controller in the brine
tank.