MODEL 63504-F63C1/63604-F63C3/73504-F68C1/73604-F68C3
48
3. E1 Flash
A. Wiring of locating board
with controller fails to work.
B. Locating board
damaged.
C. Mechanical driven
failure.
D. Faulty control board.
E. Wiring of motor with
controller is fault.
F. Motor damaged.
A. Replace wiring.
B. Replace locating board.
C. Check and repair mechanical
part.
D. Replace control board.
E. Replace wiring.
F. Replace motor.
4. E2 Flash
A. Hall component on
locating board damaged.
B. Wiring of locating board
with controller fails to work.
C. Control board is faulty.
A. Replace locating board.
B. Replace wiring.
C. Replace control board.
5. E3 or E4
Flash
A. Control board is faulty.
A. Replace control board.