MODEL: N74A1-63510/N74A3-63610/N74B1-63510B/N74B3-63610B
13
2.2.Basic Setting & Usage
A. Parameter specification
Set the time of day when use;“:”
flash.
Meter Delayed:Regenerate on
the day although the available
volume of treated water drops to
zero (0). Regeneration starts at
the regeneration time.
Meter Immediate: Regenerate
immediately when the available
volume of treated water drops to
zero (0).
Intelligent Meter Delayed: Meter
Delayed Regeneration type, but
by setting Resin Volume, Feed
Water Hardness, Regeneration
Factor, the controller will
calculate the System Capacity.
Intelligent Meter Immediate:
Meter Immediately Regeneration
Type, but by setting Resin
Volume, Feed Water Hardness,
Regeneration Factor, the
controller will calculate the
System Capacity.
Only for Time Clock Type,
regeneration by days
Only for Time Clock Type,
regeneration by hours