25
reference. When put in practice, it is subject to the different requirements of raw water
hardness and application.
3.4.Parameter Settlement
Service TimeT1
Water Treatment Capacity: Q=V
R
×K÷Y
D
m
3
Hardness of inlet water, mmol/L.
Exchange factor, mmol/L, 400 1000.
Down-flow regeneration, take 400750
Up-flow regeneration, take 4501000. If
the inlet water hardness is higher, the
factor is smaller.
Resin volumem
3
.
By hoursT1=Q÷Q
h
Hour
Average water consumption per hour ( m
3
/h )
Water treatment capacitym
3
By days T1=Q÷Q
d
Day
Average water consumption per day (m
3
/d)
Water treatment capacity (m
3
)
Backwash Time T2
Generally, it is suggested to set 1015 minutes. The higher the turbidity is, the longer
backwash time shall be set. However, if the turbidity is more than 5FTU, it is better to install
a filter in front of the exchanger.
Brine& Slow Rinse Time T3
T3=(4045)×H
R
min
Generally, T3=45H
R
min.
In this formula, H
R
——The height of resin in exchange tank (m).
Brine Refill TimeT4
T40.34×V
R
÷Brine refill speed
In this formula, V
R
—— Resin volume (m
3
).
Fast Rinse Time T5
T5=12×H
R
min.
Generally, the water for fast rinse is 36 times of resin volume. It is suggested to be
set 1016 minutes, but it should meet the requirements of qualified outlet water.