31
3.7.Trouble-Shooting
A. Control Valve Fault
Problem
Cause
Correction
1. Softener fails
to regenerate.
A. Electrical service has
been interrupted.
B. Regeneration time set
incorrect.
C. Controller damaged.
D. Motor fails to work.
A. Assure permanent electrical
service (Check fuse, plug, switch
and so on).
B. Reset regeneration time.
C. Replace controller.
D. Replace motor.
2.WIFI function
is matched
unsuccessfully
A. APP is not correct.
B. Do not match in the right
way.
C. Wireless router is
broken.
A. Android phone installs Android
APP, iphone installs IOS APP.
B. Match cell phone and valve
according to user manual.
C. Replace wireless router.
3. Regeneration
time is not
correct.
A. Time of day does not set
correctly.
B. Power failure more than
3 days, the time of day is
not correct.
A. Check program and reset time of
day.
B. Reset time of day.