4
Can choose down-flow or up-flow regeneration.
Brine refill with soft water
Brine refill with soft water, which is beneficial to increasing efficiency of regeneration; when
in brine refill and dissolve status, system also is in service(Soft water flows out from outlet),
which can save regeneration time and raise working efficiency.
Brine dry mode
It can protect the resin tank better and avoid adverse reactions of the resin tank and the
salt.
Brine draw proportionally
When the actual water consumption does not reach the set water treatment capacity, but
the time has reached the maximum interval regeneration days, the brine is absorbed
according to the proportion of actual water consumption and water treatment capacity,
which is more humanized and achieves the purpose of saving brine and water.
Leakage protection function
It can be added with induction cotton or set continuous water time or peak flow rate to close
the inlet of the valve and reduce the loss caused by water leakage.
Salt shortage alarm function
It could input one time of salt adding quantity and resin volume in system program, the
system will calculate automatically if there is salt in brine tank. When brine tank is short of
salt, it will remind "Check Remaining Salt" in Service position.
Vacation mode
If you are on vacation, you can switch to vacation mode, and it will automatically close the
valve inlet and protect the resin in the resin tank.
Maintenance and replacement of resin prompt function
When the regeneration times reach a certain number, it will prompt "Call for check up resin"
in the Service position.
WIFI control function(WIFI version)
Users can remotely check the status and control program of the valve through the APP in
cell phone.
Adjust bolt to mix up a part of raw water with soft water
When the soft water is too soft, the hardness can be adjusted by adjusting bolt.
Long outage indicator
If outage overrides 3 days, the time of day indicator “12:12" will flash to remind people to