Page #37 background image
MODEL 53515/53615/63515/63615/73515/73615
33
0.20
29.20
31.50
41.10
0.25
35.16
39.50
47.16
0.30
40.65
44.00
53.64
0.35
44.84
50.50
57.88
0.40
48.70
53.50
65.48
3).Configuration for Standard Injector and Drain Line Flow Control
Tank
Dia.
mm
Injector
Model
Injector
Color
Draw Rate
Slow Rinse
Brine Refill
Flow Rate
DLFC Holes
Quantity &
Dia
Backwash
/ Fast
Rinse
L/m
L/m
L/m
t/h
750
7702
Pink
40.65
24.58
102
0
8
900
7703
Yellow
44.00
28.00
112
φ6
10
1000
7704
Blue
53.64
34.51
110
φ6
12
Remark:
Above data for the product configuration and relevant characteristics
are only for reference. When put in practice, please subject to the
different requirements of raw water hardness and application.
Above parameter is tested under 0.3MPa inlet pressure.
Holes quantity is the holes number on DLFC. Diameter of hole is φ6,
the number refers to above table.
Injectors 7702, 7703, 7704, correspond to material numbers 5468018,
5468019, 5468020.
73515/73615 only can match with injector 7702 and 7703.
63515/63615 could match with injector 7702, 7703 and 7704.
3.4. Parameter settlement
Parameter Settlement
Service time T1
Water treatment capacity
Q=V
R
×Y
D
m
3
Hardness of inlet water (mmol/L)
Exchange factor (mmol/L) 400~1000.