MODEL 53515/53615/63515/63615/73515/73615
40
3.6. Trial Running
After installing the multi-functional flow control valve on the resin
tank with the connected pipes, as well as setting up the relevant
parameter, please conduct the trail running as follows:
A. Close the inlet and outlet valve B & C, and turn on the bypass valve A.
After cleaning the impurity in the pipe, turn off the bypass valve A. (As
Figure 1-3 shows).
B. Add calculated water to the brine tank and adjust the air check valve.
Then add solid salt to the tank and dissolve the salt as much as possible.
C. Switch on power. Press and turn to the Backwash status; when
lights on, slowly open the inlet valve B to 1/4 position, making the
water flows into the resin tank; you can hear the sound of air-out from the
drain pipeline. After all air is out of pipeline, then turn on inlet valve B
completely and clean the impurity in the resin tank until the outlet water
is clean. It will take 8~10 minutes to finish the whole process.
D. Press , and turn the status from Backwash to Brine & Slow Rinse;
lights on and enter in the process of Brine & Slow Rinse. The air
check valve will turn off when control valve finished brine draw then slow
rinse starts to work. It is about 60~65minutes for whole process.
E. Press , and turn the status from Brine & Slow Rinse to Fast Rinse.
lights on. It takes about 10~15 minutes, take out some outlet water
for testing: if the water hardness reach the requirement, and the
chloridion in the water is almost the same compared with the inlet water,
then go to the next step.
F. Press , and turn the status from Fast Rinse to Brine Refill.
lights on and it indicates the brine tank is being refilled with water to the
required level. It takes about 5~6 minutes, then add solid salt to the
brine tank.
G. Press , making the control valve return to Service status; lights
on and start to running.
Note: