MODEL 53515/53615/63515/63615/73515/73615
37
1. In control mode display status, press and enter
into program set mode, and 01 value flash;
2. Press or ,set the value to be A-01, A-02, A-03
or A-04 control mode
3. Press and hear a sound “Di”, then finish
adjustment, press to turn back.
1. In regeneration time display status, press and
enter into program set mode. and 02 flash;Press
or to adjust the hour value;
2. Press again, and 00 flash, press or
to adjust the minute value;
3. Press and hear a sound “Di”, then finish
adjustment, press to turn back.
1. In water treatment capacity display status, it shows
and 200.0. Press and enter into program set mode.
and 200 flash;
2. Press or to adjust the integer of water
treatment capacity value;
3. Press and decimal part flash. Press or to
adjust the decimal of water treatment capacity value;
4. Press to finish adjustment, press to turn
back.
1. In backwash time display status, it shows and
2-10:00. Press and enter into program set mode.
and 10 flash;
2. Press or to adjust the minutes of backwash;
3. Press and 00 flash. Press or to adjust
the seconds of backwash;
4. Press to finish adjustment, press to turn
back.