MESSAGE CAUSE CURE
OUT OF SERVICE
Water is not reaching the dispensers This happens when the turbine doesn't turn, and the electronic cir-
NO WATER
cuits receive no impulses, for example when the water supply finish-
es while a product is dispensed, or during filling at start up (the
pump doesn't work, or the group is dirty, or the solenoid valve is
jammed). Turning the vending machine off and on the signals remain
active because malfunctioning is detected once again during filling
procedure at start up. The vending machine is blocked in all its
functions, including temperature management (heater off): it's neces-
sary to fill up the water tank or check the presence of water in the
waterworks, and then to perform the filling procedure with the reset
key until a steady water jet doesn't come out. The out-of-service is
reset after having pressed the internal button the moment the pump
starts in order to perform filling; the user shall take care of continuing
the filling procedure until a regular water jet is coming out. If signal-
ing persists after dispensing, call a Service Center.
OUT OF SERVICE
This happens when the grinder mo- The vending machine keypad functions are blocked: it's necessary
NO COFFEE BEANS
tor stays in operation for more than to fill the coffee container and turn the machine off and on. It may
a certain time without closing the also be reset by pressing the internal button. If signaling persists
dosing switch. after coffee dispensing, call a Service Center.
OUT OF SERVICE
This happens when the coffee The vending machine keypad functions are blocked. If the vending
EMPTY GROUNDS
grounds tray has reached maximum machine is turned off and on again the signaling persists. The cof-
capacity. fee grounds tray must be emptied (micro-switch off for at least 5
seconds). Eight coffees before reaching the maximum coffee
grounds
number (0..... 99|, the display shows a warning message.
OUT OF SERVICE
The group was not inserted correct If by turning the vending machine off and on the signaling persists,
NO BREW. UNIT
ly in its seat, or the group presence call a Service Center. If the group is missing at start up, the vending
micro-switch doesn't work. machine does not perform filling and group reset.
OUT OF SERVICE
The vending machine has reached The vending machine keypad functions are blocked. If the vending
STOP BEVERAGE
the programmed number of drinks. machine is turned off and on again the signaling persists. To reset
vending machine functions it's necessary to enter programming and
use the RESET function in the STOP menu.
OUT OF SERVICE
The vending machine has reached The vending machine keypad functions are blocked. If the vending
STOP SOLUB.
the programmed number of soluble machine is turned off and on again the signaling persists. To reset
product 1 (or soluble product 2
or
vending machine functions see above.
OUT OF SERVICE
The vending machine has dispensed The vending machine keypad functions are blocked. To reset vend-
STOP WATER
the programmed quantity of water. ing machine functions see above. If the vending machine is turned
off and on again the signaling persists. To perform reset without
accessing programming (only in the case of it being out of service,
for example for operators that don't know the password) follow this
procedure:
While pressing the RESET key, press the A key within 3 seconds
(ref. 3, fig. 6), the LED starts to flash.
Press the C button for a short time (ref. 3, fig. 6) to confirm the
reset. If the C key is not pressed do (ref. 3, fig. 6) within 10
seconds the LED stops flashing and reset id not performed.