22
3270360_GB
Press the
key to start the cycle
The and icons remain steady: the test is run to verify the insertion of
the core probe
The cycle is run when the test is completed successfully; otherwise, a time-
controlled positive hard chilling cycle will start. The and icons remain on
CORE PROBE NEGATIVE SOFT QUICK COOLING CYCLE
WARNING: insert the needle probe correctly to run a temperature-controlled cycle.
FREEZE
Press the
FREEZE
key to select a core probe negative Soft QC
The , and
HARD
and icons blink
The display shows the room probe temperature setpoint during QC
Press or within 15 seconds to change the value
Use the e keys to change the value
Press the
key to start the cycle
The , ,
HARD
and icons remain steady: the test is run to verify
the insertion of the core probe
The cycle is run when the test is completed successfully; otherwise, a time-
controlled negative hard chilling cycle will start. The , ,
HARD
, and
icons remain on
CORE PROBE NEGATIVE HARD QUICK COOLING CYCLE
WARNING: insert the needle probe correctly to run a temperature-controlled cycle.
FREEZE
Press the
FREEZE
key to select a core probe positive Soft QC
The , ,
HARD
and icons blink
The display shows the room probe temperature setpoint during QC
HARD
Press the
HARD
key to select a core probe negative Soft QC
The
HARD
icon turns off
The display shows the room probe temperature setpoint during QC
Press or within 15 seconds to change the value
Use the e keys to change the value