24
Problem
Solution
Wireless remote not reporting in to
console.
There are dashes (--.-) on the display
console.
If any of the sensor communication is lost, dashes (--.-) will
be displayed on the screen. To reacquire the signal, press
and hold the CHANNEL/+ button for 3 seconds, and the
remote search icon will be constantly displayed. Once
the signal is reacquired, the remote search icon will
turn off, and the current values will be displayed.
The maximum line of sight communication range is 100
m and 30 m under most conditions. Move the sensor
assembly closer to the display console.
If the sensor assembly is too close (less than 1.5m), move
the sensor assembly away from the display console.
Make sure the remote sensor LCD display is working and
the transmitter light is flashing once per 60 seconds.
Install a fresh set of batteries in the remote thermo-
hygrometer. For cold weather environments, install
lithium batteries.
Make sure the remote sensors are not transmitting
through solid metal (acts as an RF shield), or earth barrier
(down a hill).
Move the display console around electrical noise
generating devices, such as computers, TVs and other
wireless transmitters or receivers.
Move the remote sensor to a higher location. Move the
remote sensor to a closer location.
Indoor and Outdoor Temperature do not
agree
Allow up to one hour for the sensors to stabilize due to
signal filtering. The indoor and outdoor temperature
sensors should agree within 2 °C (the sensor accuracy is ±
1 °C).
Use the calibration feature to match the indoor and
outdoor temperature to a known source.
Indoor and Outdoor Humidity do not agree
Allow up to one hour for the sensors to stabilize due to
signal filtering. The indoor and outdoor humidity sensors
should agree within 10 % (the sensor accuracy is ± 5 %).
Use the calibration feature to match the indoor and
outdoor humidity to a known source.
Display console contrast is weak
Replace console batteries with a fresh set of batteries.