Figure 4.5
Connect L, N and protective conductor to the AC terminal in accordance with the
label.
To do this, the insulated earthling conductor must be 5mm longer than the insulated L and N
conductors! L and N must not be swapped. The ground wire shall be larger than phase
conductor.
Figure 4.6
5) Aim the terminals on the straight plug to the holes of the grommet, and then compress
them together.
Figure 4.7