39ST620RF INSTRUCTION MANUAL
DEFAULT PROGRAMMES
Programme Output Weekday Weekend
1
ON 6:00 AM 6:00 AM
TEMP 21 ºC 21 ºC
2
ON 8:00 AM 8:00 AM
TEMP 14 ºC 14 ºC
3
ON 11:00 AM 11:00 AM
TEMP 21 ºC 21 ºC
4
ON 1:00 PM 1:00 PM
TEMP 14 ºC 14 ºC
5
ON 4:00 PM 4:00 PM
TEMP 21 ºC 21 ºC
6
ON 9:00 PM 9:00 PM
TEMP 14 ºC 14 ºC
Temperature
Scale: Celsius
Tolerance: Less than ± 0.5 ºC at 25 ºC
Sampling Rate: Every 15 seconds
Display Range: 0.0 ºC to + 45.0 ºC
Display Resolution: 0.5 ºC
Set Temperature Range: 5.0 ºC to + 35 ºC
Resolution: 0.5 ºC