20
SERVICE MENU
Entrance to the service menu:
Password [0000] OK
Services settings
range
fact.
Heating circuit
Heat source
Protection
Room thermostat
Yes/No
No
Temperature correction:
T1 Circuit sensor
T2 External sensor
T3 Return sensor
T4 Boiler sensor
-4..+4ºC
-4..+4ºC
-4..+4ºC
-4..+4ºC
0
0
0
0
External sensor
Off/On
On
Manual control
Screed drying:
Active
Program selection: P1-P7
Yes/No
P1..P7
No
P1
Restore defaults settings
Yes/No
No
Heating circuit
range
fact.
Support
Off/On
On
Kind of the system:
Radiators system
Underfloor heating
Und.
Control method:
Weather control
Continous control
Weat.
Weather control *:
Heating curve
Curve parallel move
-15..15K
0
Preset temperature
20..40ºC
35
Decrease of work mode
0..15K
10
Decrease of thermostat *
0..30K
10
OFF by thermostat*
Yes/No
Yes
Start pump temp.
10..70ºC
35
Min. temperature
5..40ºC
20
Max. temperature
20..50ºC
40
Valve full opening time
60..200s
140
Valve input dead zone
0.0..2.0K
1.0
Valve dynamic
1..6
2
Valv delay
30..255
200
Heat source
range
fact.
Support
Off/On
On
Histeresis
1..30K
8
Min. temperature
10..70ºC
30
Max. temperature
50..90ºC
75
Buffer
Yes/No
No
Buffer preset temp.*
30..75ºC
60
HW priority
Yes/No
No
Cooling temp.
80..100ºC
88
OFF by thermostat*
Yes/No
No
Increrase temp.
1..20ºC
5
Protection
range
fact.
Return sensor
Off/On
Off
Min. temperature*
30..65ºC
40
Histeresis*
2..15K
8
Closing the valve*
0..50%
10
Frost protection
Off/On
On
Frost protection delay*
1..10h
4
Frost protection temp.*
5..10ºC
7