9
Continous control the preset
temperature of water in the heating circuit
is constant at the set value, without the
impact of changes in external
temperature.
Preset temperature setting in
Service menu (described in the
manual).
User’s main menu
Work mode
This option is used to switch on the respective
modes of work of the controller according to
user preferences.
To change the work mode to select:
Main menu Work mode
OFF - the controller turns off the
heating circuit. The frost protection
function remains active as long as it is
enabled in the service menu.
Activating this work mode also turns
off the heat source. The heat source
is not turns off during active function
heating buffer.
Auto - preset temperature in the
room changes according to the time
program. In periods of "day" is setting
Preset temperature. In periods of "night"
is setting (Preset temperature - Decrease
of work mode).
Comfort - preset temperature in the
room is constant and corresponds to the
entered value Preset temp.
Economy - preset temperature in the
room is constant and corresponds to the
entered value temperature (Preset
temperature - Decrease of work mode).
Auto-Eco - preset temperature in the
room changes according to the time
program. In periods of "day" is set Preset
temperature. In periods of "night" heating
circuit is completely turns off. The frost
protection function remains active as long
as it is enabled in the Service menu.
Schedule
The time intervals allow the introduction of
decrease preset temperature within a
specified time period for the heating circuit
and the turns on or turns off heat source, eg.
at night or when user leave the heated rooms.
As a result, the preset temperature can be
lowered automatically without loss of heat
comfort in the room.
Activation of time intervals in:
Main menu Schedule
and select a time schedule for the heating
circuit or heat source.
Decrease night time for the heating circuit and
the work of heat sources can be defined
separately for every day of the week: Monday
- Sunday.
Select the decrease of the preset temperature
and the beginning and end of a given time
interval.
Working of decrease temperature in the time
intervals are designated as "day" - this
corresponds to the Preset temperature and
"night" - corresponds to the Decrease of
work mode.
Action at intervals for the heat source are
marked as - heat source is turned on and
- a heat source is turned off.
Main menu
Information
Work mode
OFF
Auto
Comfort
Economy
Auto-Eco
Schedule
Circuit
Heat source
Summer\Winter
SUMMER mode:
OFF, ON, Auto
Summer mode ON temp.
[range 5..35ºC, fact.20]
Summer mode OFF temp.
[range 1..22ºC, fact.18]
General settings
Clock
Screen brightness
Screen contrast
Sound
Language
Service settings