82 | SAMLEX AMERICA INC. SAMLEX AMERICA INC. | 83
TABLE 6.1 LED AND BUZZER INDICATIONS
Status
Green LED
marked “ON”
(12, Fig 2.1)
Red LED
marked
“Fault” (13, Fig
2.1)
Buzzer
Seen during Power-On
Sequence
Indicates completion of
Power-On Sequence after
Power ON/OFF Button is
pressed for 2 sec
Flash 3 times Off Off
Seen during Power-Off
Sequence
Indicates completion of
Power-Off Sequence after
Power ON/OFF Button is
pressed for 5 sec
On On Off
Normal charging Flash 1 time per sec Off Off
Equalization charging Flash 2 times per
sec
Off Off
Inverting (Discharging) On Off Beep per 3 second
(Default Off)
Low battery alarm On Flash 1 per sec Beep per 1 second
Power saving Flash 1 time per
3 sec
Off Off
Standby Off Off Off
Fault Off On On
6.4 OPTIONAL REMOTE CONTROL EVO-RC (see Appendix A) FOR
PROGRAMMING OF MODES OF OPERATION AND PARAMETERS
Optional Remote Control Model EVO-RC (Fig 2.4) will be required for more advanced control
and monitoring. Please see separate Owner’s Manual for EVO-RC at Appendix A. The Remote
Control comes with 10M / 33 ft., RJ-45 Data Cable. The Remote plugs into RJ-45 Jack on
the front panel of the unit (7, Fig 2.1). It has provision for Data Logging using SD Card of up
to 16 GB (FAT16 / FAT32). It also has its own Real Time Clock and Super Capacitor Type of
Battery.
Detailed messaging is available through its LCD display and LEDs. This remote will also
be required for programming of various parameters to suit specic requirements. Each
programmable parameter has a Default Value. This unit has been shipped with the various
parameters set at the Default Values. Programmable and Default values are shown in Tables
6.2 to 6.6:
SECTION 6 | Operation, Protections and Troubleshooting