EB 8546 EN 11
Mounting the supply pressure regulator
3.1.1 Directionofow
In the compact supply pressure regulators
(Types4708-10xx/-11xx/-14xx and
-17xx), the direction of ow can be changed
as follows:
1. Unscrew the two fastening screws and lift
the supply pressure regulator off its con-
necting plate.
2. Remove the diverting gasket, turn it 180
degrees and reposition it as shown in
Fig.3.
Î The long rubber nger of the gasket must
always point in the direction of the regu-
lator outlet.
3. Fasten the supply pressure regulator onto
the connecting plate.
4. Stick the adhesive label included in the
accessories over the arrow of the name-
plate, making sure that the arrow indi-
cates that the supply air ows in the op-
posite direction.
G
4708-112.
0
6
3-....
0
6
3-....
4708-112.
G
Connecting plate
Standard label
Gasket
Connecting plate
Adhesive label with arrow
Fastening screws
Long rubber nger always pointing towards the regulator outlet
Supply
pressure
regulator
Fig.3: Changing the direction of ow in compact supply pressure regulators