12 EB 8546 EN
Mounting the supply pressure regulator
3.2.1 Turning the supply pres-
sure regulator
The supply pressure regulator can be turned
on its connecting plate to allow the set point
screw to face either up or down.
1. Unscrew the two fastening screws and lift
the supply pressure regulator off its con-
necting plate.
2. Pull the diverting gasket out of the regu-
lator and keep it in this position.
3. Turn the regulator 180 degrees and rein-
sert the gasket. In this way, you keep the
bore assignment of the gasket for supply
air input and regulator outlet.
Î The long rubber nger of the gasket must
always point in the direction of the regu-
lator outlet (reduced supply pressure).
4. Fasten the supply pressure regulator onto
the connecting plate.
Diverting gasket
Front and back view
Regulator outlet
Supply air input
depending on the
position of the
gasket
Regulator outlet (long rubber nger)
Supply air input
Regulator facing upward
Supply air input
(Supply) >
Diverting gasket
Long rubber nger
always pointing
towards outlet
Regulator facing downward
Fastening screws
Connecting plate or adapter plate
Fig.4: Turning the supply pressure regulator on its connecting plate or adapter plate