Troubleshooting
Samsung Electronics 4-27
ߥࣗߧɇЇϩUɇ˝ͱϑϑɵцƊцΧϩͱ
4-6-1 Indoor
Indoor unit display
X (Operation)
࣍Uʪ˙θͱϑϩ࣎ǹ࣍Ɵʪθ࣎ǹ࣍ϩʪθ࣎
X (Operation)
ǹ࣍Uʪ˙θͱϑϩ࣎
(Reservation) X (Fan) X (Filter)
Symptom
In case of open or short circuit of indoor temperature sensor
Failure
Short or leakage of the corresponding sensor
Yes
No
No
In this case, is the resistance
ЭɇЇʪͱЇϩͱ˙θɇ˝ʪϩ˵ʪϩʪΧʪθɇϩЇθʪ
table on the right?
Yes
Is indoor temperature
sensor disconnected from the connector
in PCB?
Restart the system after
replacing the PCB
Restart the system after connecting
to the PCB connector
Indoor temperature sensor
failure (replace)
ŵʪͱЭʪϩ˵ʪʒͱͱθϩʪΧʪθɇϩЇθʪϑʪϑͱθ
connector from the PCB and measure the
resistance between two terminals
ߥࣗߧࣗߢࣗߢÃʒͱͱθϩʪΧʪθɇϩЇθʪϑʪϑͱθ࣍ͱΧʪࢥϑ˵ͱθϩ࣎
Current
temperature
(°C)
Resistance
࣍ץ࣎
40 5.800
35 6.900
30 8.300
25 10.00
20 12.10
15 14.70
10 18.00
5 22.00
028.30
-5 33.90
-10 42.30
<Temperature sensor
θʪϑϑϩɇʀʪЭɇЇʪ