65
English
Installation manual
Option SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
Explanation - -
Dual fuel (heater lock)
setting
Dual fuel (HP lock)
setting
- Control variables when using hot water / external heater (*4)
Indication
and Details
Indication Details - Indication Detail Indication Detail - Indication
Details
0 Disuse
2 -
0 Disuse 0 Disuse
-
0
At the same
time as
thermo on
No delay
1 1 1
At the same
time as
thermo on
10 minutes
2 2 2
At the same
time as
thermo on
20 minutes
3 3 3 1.5 °C No delay
4 4 4 1.5 °C 10 minutes
5 5 5 1.5 °C 20 minutes
6 6 6 3.0 °C No delay
7 7 7 3.0 °C 10 minutes
8 8 8 3.0 °C 20 minutes
9 9 9 4.5 °C No delay
A A A 4.5 °C 10 minutes
B B B 4.5 °C 20 minutes
C C C 6.0 °C No delay
D D D 6.0 °C 10 minutes
E E
E 6.0 °C 20 minutes
F
Cannot be
used
F
Cannot be
used
Option SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
Explanation PAGE - - -
Forcing FAN Operation for Heating
and Cooling
Whether to use UV LED / whether to use BLE Onboarding / whether to
allow fan speed control during auto mode
/ MDS (motion detection sensor) control UX type(*5)
Indication
and Details
Indication Details - - - Indication
Details
Indication
Detail
Cooling Fan
Setting
Heating
Fan Setting
UV
LED
BLE
Onboarding
Whether
to allow
fan speed
control
during auto
mode
MDS (motion detection
sensor) control UX type
3 - - -
0 Disuse Disuse 0 Disuse Disuse Disuse
Fan speed and power
saving mode can be set
simultaneously
1 Disuse
Use (Fan:
User
setting)
1 Use Disuse Disuse
Fan speed and power
saving mode can be set
simultaneously
2 Disuse
Use (Fan:
High)
2 Disuse Use Disuse
Fan speed and power
saving mode can be set
simultaneously
3 Disuse
Use (Fan:
Low)
3 Use Use Disuse
Fan speed and power
saving mode can be set
simultaneously