● Code :
C3-2411
C3-3411
C3-4411
C3-5411
● Error message
Yellow imaging unit
Magenta imaging u
● Symptom / Cause :
The data of CRUM is not detected.
1. Imaging Unit is not placed in the set.
2. Physical obstacle is jamming the electronic signal t
3. The signal from set is not proper.
● Troubleshooting method :
1. Open the front cover.
Remove the waste toner container.
Open the inside cover.
2. Is the imaging unit placed in the set or not?
YES! NO! → Place the imaging unit in the set
.
↓
Pull out the imaging unit and check the modular j
Is there any contaminations or obstacles?
YES! NO! → Is the modular jack fixed in proper
↓ YES! NO! → Replace the imaging
↓ ↓
↓ Check whether the electronic signal i
↓
Sweep the contamination or remove the obstacles
Install the imaging unit and do the reverse of No.1.
Is there the error message?
YES! NO! → It’s done.
Check whether the electronic signal is proper or n
● Replacement part
- K Imaging Unit : CLT-R607K
- C Imaging Unit : CLT-R607C
- M Imaging Unit : CLT-R607M
- Y Imaging Unit : CLT-R670Y
- JC92-02129A : PBA-ENGINE (CLX-9350ND)
- JC92-02239A : PBA-ENGINE (CLX-9250ND)
Service Manual
CLX-9250/9350 series
7-
is not installed. Install it.
it is not installed. Install it.
not installed. Install it.
not installed. Install it.
t. Check the connector and engine board.
SAMSUNG ELECTRONICS