7. Trouble
s
7.4 Other errors
7.4.1 OPE problem
Symptom
The LCD panel does not display anything on.
Possible cause
1. Power is not supplied to OPE.
2. OPE is defective.
Troubleshooting method :
1. Is power supplied to OPE?
Yes : If there is any problem, check if power is sup
p
Check if power is supplied to engine controlle
r
- CN4 : Pin No.9,12 , Check the voltage b
y
- U2 : Pin No.2 , Check the voltage by DV
M
Replace the SMPS board.
No : Replace the OPE board.
Service Manual
CLX-9250/9350 series
7-1
s
hooting
p
lied to HUB PBA.
r
.
y
DVM. (Normal value : 5V)
M
. (Normal value : 3.3V)
SAMSUNG ELECTRONICS