ENGLISH-56
COMMISSION REGULATION (EU) No 813/2013
I)
ECODESIGN REQUIREMENTS FOR SPACE HEATER
II)
A Model(s) : AE050JXYDEH
B Air-to-water heat pump : yes
C Water-to-water heat pump : no
D Brine-to-water heat pump : no
E Low-temperature heat pump : no
F Equipped with a supplementary heater : no
G Heat pump combination heater : no
H
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pump,
parameters shall be declared for low-temperature application.
I Parameters shall be declared for average climate conditions.
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
Item
(J)
Symbol
(K)
Value
(L)
Unit
(M)
N Rated heat output(
*)
Prated
(o)
5 kW P
Seasonal space heating energy
eciency
η
s
125 %
Q
Declared capacity for heating for part load at indoor temperature 20 °C and
outdoor temperature T j
R
Declared coecient of performance or primary energy ratio for part load at indoor
temperature 20 °C and outdoor temperature T j
-
Tj = -7°C Pdh 4.2 kW
-
Tj = -7°C COPd
(S)
2.24 -
Tj = +2°C Pdh 2.5 kW Tj = +2°C COPd
(S)
2.90 -
Tj = +7°C Pdh 1.6 kW Tj = +7°C COPd
(S)
4.02 -
Tj = +12°C Pdh 0.7 kW Tj = +12°C COPd
(S)
7.25 -
T Tj = bivalent temperature Pdh 4.7 kW T Tj = bivalent temperature COPd
(S)
1.90 -
U Tj = operation limit temperature Pdh 4.7 kW U Tj = operation limit temperature COPd
(S)
1.90 -
V
For air-to-water heat pumps
Tj = -15°C (if TOL < -20°C)
Pdh - kW V
For air-to-water heat pumps
Tj = -15°C (if TOL < -20°C)
COPd
(S)
- -
W Bivalent temperature Tbiv -10 °C X
For air-to-water heat pumps:
Operation limit temperature
TOL -10 °C
Y Cycling interval capacity for heating Pcych - kW Z Cycling interval eciency COPcyc
(AA)
- -
AB Degradation co-ecient(
**)
Cdh 0.9 - AC
Heating water operating limit
temperature
WTOL - °C
AD Power consumption in modes other than active mode AE Supplementary heater
AF O mode P
OFF
0.080 kW N Rated heat output(
*)
Psup - kW
AG Thermostat-o mode P
TO
0.011 kW
AJ Type of energy inputAH Standby mode P
SB
0.011 kW
AI Crankcase heater mode P
CK
0.000 kW
AK Other items AK Other items
AL Capacity control variable
(AM)
AN
For air-to-water heat pumps :
Rated air ow rate, outdoors
- 51 m
3
/h
(AO)
AP
Sound power level, indoors/
outdoors
L
WA
-/61 dB
AR
For water-/brine-to-water heat
pumps: Rated brine or water ow
rate, outdoor heat exchanger
- - m
3
/h
(AO)
AQ Emissions of nitrogen oxides NOx - mg/kWh
AS For heat pump combination heater AS For heat pump combination heater
AT Declared load prole - AU Water heating energy eciency η
wh
- %
AV Daily electricity comsumption Q
elec
- kWh AW Daily fuel consumption Q
fuel
- kWh
AX Contact details http://www.samsung.com
AY
(*)
For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a
supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
AZ
(**)
If Cdh is not determined by measurement then the default degradation coecient is Cdh = 0.9.
BA
1)
Precautions as described in the installation/user manual must be taken when assembling, installing and maintaining this product.
BB
2)
If you are a professional looking for information on non-destructive disassembly and dismantling, please send an email to: erims.sec@samsung.com