What happens if the PHE Outlet thermistor is SHORT or OPEN in my Samsung MIM-E03EN Heat Pump?
- TTimothy BakerAug 6, 2025
If the PHE Outlet thermistor is SHORT or OPEN, error codes will be displayed on the wired remote controller.
What happens if the PHE Outlet thermistor is SHORT or OPEN in my Samsung MIM-E03EN Heat Pump?
If the PHE Outlet thermistor is SHORT or OPEN, error codes will be displayed on the wired remote controller.
What happens if the Zone1 Water Outlet Thermistor is SHORT or OPEN in my Samsung MIM-E03EN Heat Pump?
If the Zone1 Water Outlet Thermistor is SHORT or OPEN, error codes will be displayed on the wired remote controller.
What happens if the Zone 2 Water Outlet Thermistor is SHORT or OPEN in my Samsung Heat Pump?
If the Zone 2 Water Outlet Thermistor is SHORT or OPEN, error codes will be displayed on the wired remote controller.
Explains basic operation modes like Auto, Cool, and Heat.
Details on operating the unit for domestic hot water supply.
Guide on modifying temperature settings for heating and cooling.
Procedures for configuring target temperatures for various modes.
How to view the current operational status of the unit.
Information on reducing operational noise levels.
How to operate the unit at low temperatures when away.
Configuring daily, weekly, or yearly operating schedules for efficiency.
Viewing and setting energy usage and consumption targets.
Explains time-division multi variables for specific product models.
Step-by-step guide to configure various unit settings.
Example procedure for setting the current time on the controller.
Details on advanced features available via the remote controller.
Options and settings for installation and service technicians.
Procedure for backing up and restoring unit settings using an SD card.
Specific field settings for AE model Air to Water Heat Pumps.
Configuration parameters related to temperature limits for heating/cooling.
Settings for water law and room thermostat control with 2 WLs.
User options for domestic hot water (DHW) tank heating.
User options for heating devices, including backup heaters.
User options for extra functions like Outing mode and Smart Grid.
Field settings specific to the DVM Hydro unit.
Field settings specific to the DVM Hydro unit HT.
General guidance on regular unit checks and inspections.
Procedures for emergency heating or hot water provision.
Explains communication errors between controller and unit.
Troubleshooting for water pump and flow sensor issues.
Lists and explains various error codes displayed by the unit.