EasyManua.ls Logo

Samsung MIM-E03CN - User Manual

Samsung MIM-E03CN
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Air to Water Heat Pump
User manual
Wired remote controller MWR-WW10N / Control Kit MIM-E03CN
Thank you for purchasing this Samsung Product.
Before operating this unit, please read this user manual carefully and retain it for future
reference.

Other manuals for Samsung MIM-E03CN

Questions and Answers

  • K
    Kelsey EricksonAug 12, 2025
    Why is the safety valve dripping on my Samsung MIM-E03CN Heat Pump?
    • S
      Steve BuchananAug 12, 2025
      If the safety valve of your Samsung Heat Pump is dripping, it's normal for some dripping to occur due to water expansion during heating. However, if the dripping is severe, the safety valve might need replacement. Another solution is to fit an expansion vessel.
  • J
    James HernandezAug 16, 2025
    How to fix a Samsung MIM-E03CN that is not producing hot water?
    • B
      brian47Aug 16, 2025
      If hot water is not coming out of your Samsung Heat Pump, first, check if there is power on the power supply terminal on the thermostat. If the thermostat is set too high, reduce the setting by 5 °C and press the reset button.
  • T
    tuckerteresaAug 19, 2025
    What to do if my Samsung Heat Pump heating is not working?
    • M
      Michael MorrowAug 19, 2025
      If your Samsung Heat Pump is not heating, check if there is any power on the power supply on the connector of the heating element between black and yellow/green wires. If the power supply is OK, press the reset button on the fuse/safety cut-off.
  • R
    Rebecca ScottAug 25, 2025
    Why is my Samsung Heat Pump water not warm enough?
    • J
      James WhiteAug 25, 2025
      If the water from your Samsung Heat Pump isn't warm enough, adjust the thermostat using a standard screwdriver. Also, check the resistance of the heating element on the connector of the heater bundle and the condition of the internal wiring. Finally, ensure the UX mixing valve is correctly adjusted to your preferred temperature.
  • J
    Jack JohnsonAug 27, 2025
    What to do if the leak warning outlet is dripping on my Samsung MIM-E03CN?
    • L
      lewiskimberlyAug 27, 2025
      If the leak warning outlet on your Samsung Heat Pump is dripping, check the heating element o-ring seal and all connections to ensure they are properly tightened.
  • N
    Nicole NortonAug 30, 2025
    What happens if the PHE Outlet thermistor is SHORT or OPEN in my Samsung Heat Pump?
    • L
      Linda DayAug 31, 2025
      If the PHE Outlet thermistor is SHORT or OPEN, error codes will be displayed on the wired remote controller.
  • S
    Shannon KellySep 4, 2025
    What happens if the Zone1 Water Outlet Thermistor is SHORT or OPEN in my Samsung MIM-E03CN?
    • S
      Scott WhiteSep 4, 2025
      If the Zone1 Water Outlet Thermistor is SHORT or OPEN, error codes will be displayed on the wired remote controller.
  • C
    coltonpowersSep 7, 2025
    What happens if the Zone 2 Water Outlet Thermistor is SHORT or OPEN in my Samsung Heat Pump?
    • C
      chandlernicholasSep 7, 2025
      If the Zone 2 Water Outlet Thermistor is SHORT or OPEN, error codes will be displayed on the wired remote controller.

Summary

Safety Information

General Safety Warnings

Covers general warnings and cautions for safe operation.

Installation Safety

Guidelines and warnings for the safe installation of the unit.

Power Supply Safety

Precautions related to the unit's power supply connection and usage.

Operation Safety

Critical safety advice for operating the heat pump unit.

Cleaning Safety

Safety instructions for cleaning the heat pump unit components.

Remote Controller Operation

Operating Basic Mode

How to use the remote controller for basic functions.

Auto Mode Operation

Details on how the unit automatically adjusts settings.

Cool Mode Operation

Instructions for operating the unit in cooling mode.

Heat Mode Operation

Instructions for operating the unit in heating mode.

Domestic Hot Water (DHW) Mode

How to operate the unit for domestic hot water supply.

Adjusting Desired Temperature

Step-by-step guide to adjusting temperature settings.

Setting the Target Temperature

How to configure the desired temperature setpoints.

Power Smart Features

Operation Status Display

How to view the current operational status of the unit.

Quiet Mode

Instructions for enabling quiet mode to reduce noise.

Outing Mode

How to set the unit to maintain low temperature when away.

Energy-Saving Operation

Setting Schedules

Guide to configuring daily, weekly, or yearly operational schedules.

Energy Usage and Settings

How to monitor and configure energy consumption parameters.

TDM Variables Explained

Detailed explanation of Time-Division Multi (TDM) variables.

Setting Options

How to Set Options

General guide for configuring various operational settings.

Wired Remote Controller Settings

Specific configuration options for the wired remote controller.

Current Time Setting Example

Step-by-step procedure for setting the current time.

Installation;Service Mode

Additional Remote Controller Functions

Accessing and utilizing advanced functions of the remote controller.

Service Timer and Zone Options

Configuration settings for service timers and indoor zone options.

Indoor Zone and Connection Info

Settings related to indoor zone configuration and unit connections.

Device Info and Field Settings

Viewing system information and adjusting field setting values.

Self-Test Mode Details

Information and procedures for using the self-test mode.

Indoor Unit Options Configuration

Detailed settings for various indoor unit options.

Field Settings Upload;Download

Procedure for uploading and downloading field settings via SD card.

Field Setting Mode

AE*** Model Field Settings

Specific field setting values for Air to Water Heat Pump AE models.

Remote Controller Setting Ranges (Code 10**)

Parameter ranges for remote controller settings identified by Code 10**.

Field Settings (FSV Code 20**)

Configuration details for Field Setting Value Code 20** related to Water Law.

Water Law Details (Code 20**)

Explanation of Water Law settings and their parameters for Code 20**.

External Room Thermostat Options

Configuration and usage of external room thermostat options.

DHW Tank Field Settings (FSV Code 30**)

User-selectable options for Domestic Hot Water (DHW) tank heating.

DHW Heating Application Details

Information on DHW application and heat pump variables for DHW.

DHW Tank Temperature Control

Settings for DHW tank temperature control and time variation.

Booster Heater Control for DHW

Time variation and control variables for the booster heater in DHW mode.

Booster Heater Examples and Disinfection

Examples of booster heater usage and disinfection function setup.

Solar;DHW Thermostat & Energy Metering

Additional options for solar/DHW thermostat and energy metering.

Heating Field Settings (FSV Code 40**)

Field setting values for various heating devices specified by Code 40**.

Heating Options and Variables

Details on heat pump, backup heater, and boiler settings for heating.

Mixing Valve, Inverter Pump, and Zone Control

Installation options for mixing valves, inverter pumps, and zone control.

Extra Functions and Outing Mode

User options for extra functions and settings for Outing Mode.

PV Control Settings

Configuration options for Photovoltaic (PV) control for energy saving.

Smart Grid Control

Settings for integrating the unit with a Smart Grid system.

DVM Hydro Unit Settings (AM****NBD***)

Field setting values for DVM Hydro units of model AM****NBD***.

DHW and Heating Settings

Settings related to DHW operations and various heating functions.

DVM Hydro Unit HT Settings (AM***TNBF**)

Field setting values for DVM Hydro Unit HT of model AM***TNBF**.

Water Law and DHW Functions

Settings related to Water Law and Domestic Hot Water functions.

Field Specification Functions

Detailed functions requiring specific field setting configurations.

Code 20** and 30** Details

Explanations and parameters for Field Setting Codes 20** and 30**.

Code 401* Priority Settings

Priority settings for hot water and heating operations as per Code 401*.

Code 50** Extra Functions

User-selectable options for various extra functions designated by Code 50**.

Maintaining the Unit

Maintenance Activities

Information on regular checks and inspections for unit availability.

Emergency Heating;Hot Water

Procedures for activating emergency heating or hot water supply.

Troubleshooting Tips

Error Code Explanations

Explanation of various error codes displayed on the remote controller.

Communication Errors

Troubleshooting guidance for communication errors between units.

Water Pump & Flow Sensor Issues

Guidance for resolving issues related to water pumps and flow sensors.

Error Codes

Hydro Unit Error Codes

List and explanations of error codes specific to the Hydro Unit.

Outdoor Unit Error Codes

List and explanations of error codes specific to the Outdoor Unit.

Questions or Comments

Contact Information

Details for contacting Samsung support for questions or comments.

Samsung MIM-E03CN Specifications

General IconGeneral
BrandSamsung
ModelMIM-E03CN
CategoryHeat Pump
LanguageEnglish