50
Field setting mode
English
Field Setting Mode
࡙ 3023: Offset temperature of DHW’s thermo on (Only Hydro Unit / Not Hydro Unit HT)
ƟʪΧʪθɇϩЇθʪͱ˙²ͱϩǮɇϩʪθƟɇƊʪϩϩ˝ϩʪΧʪθɇϩЇθʪͱ˙²ͱϩǮɇϩʪθƟɇߢ
ĘUƟʪΧʪθɇϩЇθʪͱ˙²ͱϩǮɇϩʪθƟɇAͱʒʪࢄߤߡߣߢࣔAͱʒʪࢄߤߡߣߣAͱʒʪࢄߤߡߣߤ
࡙ 3024: When Heating and DHW mode is operating at the same time and heating mode is operating
based on leaving water temperature with Thermo off, heating will operate for number of
minutes stated in #3024 after every time maximum DHW operation time ends
࡙ 3025: DHW operation time when heating and DHW mode is operating at the same time
࡙ 3026: Heating operation time when heating and DHW mode is operating at the same time
303*: Booster heater variables for combination with heat pump
࡙ 3031: Application of Booster heater
࡙ 3032: Booster heater startup delay timer
࡙ ߤߡߤߤࡠ9ͱͱϑϩʪθ˵ʪɇϩʪθͱЭʪθϑ˵ͱͱϩϩʪΧʪθɇϩЇθʪ࣍ƊǤࢄߤߡߤߤࡡUʪ˙ɇЇϩ࢑ߡઑA࢑ࡡŵɇ˝ʪߡߥઑA࣎
304*: Setting hot water tank disinfection period
࡙ 3041: Application of disinfection function
࡙ 3042: Scheduling (day)
Sunday Monday Tuesday Wednesday Thursday Friday Saturday AllDay
01234567
࡙ 3043: Starting time (hour)
࡙ 3044: Target tank temp
࡙ 3045: Duration time (After reaching the target temperature)
࡙ 3046: Maximum duration of disinfection operation (disinfection operation stops after the specified
duration)
࢘
Disinfection operation can start if a booster heater is connected.
࢘
Check the booster heater capacity and booster heater failure , if disinfection operation does not
work normally over the maximum duration. (E919 error)
࡙ 3061: Interlock between solar pump and hot water
ࣕ 0: Hydro unit ‘s operation regardless of solar pump activation
ࣕ 1: Hydro unit’s stop when solar pump is operating
ࣕ 2: Disabled
ࣕ 3: Defrost signal output when entering defrost mode
࡙ Code 401*
ࣕ Space/DHW heating priority and control variables
࡙ 4011: Priority setting of simultaneous operation both hot water and heating
ࣕ 0: Hot water operation has priority. (The related operation is followed with 302*)
ࣕ 1: Heating operation has priority. (If an ambient temperature < 4012, hot water operation is
neglected.)