Appendix
Display Explanation Error Source
904 DHW tank temperature sensor error Hydro Unit
906 Refrigerant gas inlet (PHE) temperature sensor (open/short) Outdoor Unit
907 Error due to pipe rupture protection Hydro Unit
ߪߡߩ Error due to freeze prevention (Re-operation is possible) Hydro Unit
909 Error due to freeze prevention (Re-operation is impossible) Hydro Unit
910 Water temperature sensor on water outlet pipe is detached Hydro Unit
911 Flow Switch Off Error, When Water pump is running Hydro Unit
912
Normal flow rate error
in case of normal flow rate in 10min during water pump signal is
OFF
Hydro Unit
913 Six times detection for Flow Switch Error (Re-operation is not possible) Hydro Unit
914 Error due to incorrect thermostat connection Hydro Unit
915 Error on DC fan (Non-operating) Hydro Unit
916 Mixing valve sensor error Hydro Unit
917 Water Tank Sensor configuration error Hydro Unit
919
Error that the set temperature for disinfection operation is not
reached, or, after reaching, the temperature fails to continue for the
requested time
Hydro Unit
920 FSV SD card data error Hydro Unit