Installation/Service mode
Step 1 Step 2 Step 3 Description Default
Heat pump options
Away mode settings
Water Law 2
temperature (5016)
 
DHW tank
temperature (5019)
 
DHW heat pump
settings
Max temp for heat
pump (3021)

(*2)

(*2)
Heat pump thermo off
hysteresis (3022)
 
(*1)
Heat pump thermo on
hysteresis (3023)
 
Min heating operating
time (3024)
1 Min to 20 min. 5 min.
Max hot water
operating time (3025)
5 Min to 95 min. 30 min.
Max heating
operating time (3026)
30 Min to 600 min. 180 min.
PV control / Peak
power control (5041,
5081)
On
/
Off Off
When
On
is selected,
select from PV control
and Peak power
control
PV control
Note 4)
Frequency ratio
control (5051)
On
/
Off Off
Smart grid control
(5091)
On
/
Off Off
Booster heater (3031)
On
/
Off On
Backup heater (4021)
On
/
Off Off
External heater (4026)
On
/
Off Off
Backup boiler (4031)
On
/
Off Off
Output type settings
(6041)
2Way valve / Zone
pump
2Way valve
Heat pump status
Heat pump status
display